1.The bucket elevator
must be securely mounted on a solid concrete foundation. Concrete
foundation surface should be flat and present as a horizontal state to
ensure well-installed bucket elevator can achieve vertical requirements.
Middle and upper casing section of a higher height bucket elevator should
be connected with the neighbouring buildings in order to increase its
stability. Firstly, please install the lower part, fix the anchor bolt,
and then install the middle casing and upper casing. After complete the
installation, please adjust and correct the vertical height, upper and
lower shaft should be parallel to each other, and shafts should be in
the same plane. When install the bucket elevator
with a lower height , you can connect the upper ,middle and lower
casing well first on the ground, and then hang the complete set
vertically and fix it on the concrete foundation.
2. After completing the installation of casing, you can install the
chain and bucket. The u-shape screw which is used for connect the
buckets, it is not only a chain connector, but also a fixture of
buckets. U-screw nuts must be tighten and locked securely, after the
installation of chain and bucket, please adjust it to get a proper
tension.
3.Add the appropriate amount of oil or grease in the gearbox and bearing respectively, reducer should be lubricated with industrial gear oil, bearing seat can be lubricated with calcium or sodium base grease.